Application The most professional brand service
Application The most professional brand service

Four-Channel strobe Light Controller

Product features:

The four-channel strobe light controller supports independent multi-channel adjustment, featuring high-frequency accuracy and synchronous triggering for high-speed vision inspection applications.


Product advantage:

technical specifications:


ModelAD-DLC200-4Description
Input VoltageAC100~240V/50Hz
Input Current4.2A/115VAC; 2.1A/230VAC
Number of Channels4 Channels
Output VoltageDC24V
Max. Continuous Current2A per Channel
Light Emission ModePulse ModePulse width adjustable
Continuous ModeSoftware controlled, stays ON after trigger, turned OFF via software
Switching ModeIn internal trigger mode, outputs continuously according to set cycle and pulse width; in external trigger mode, output synchronizes with the trigger signal
External TriggerTrigger signal DC12-24V
Trigger ModeInternal TriggerSoftware trigger
Self-Trigger Cycle1ms~1000msSet the cycle time for each channel via software
Trigger Frequency1~1500HzExternal trigger signal frequency range
Trigger Delay1ms~300msSet via software
Trigger Pulse Width1μs~1000μsSet via software
Response Time<10μsDelay time from external trigger input to light source output
Response Frequency≤1500HzMaximum frequency of the external trigger signal
Output Signal4 Channels0-5V level signal, maximum output current 10mA
Communication MethodRS232/TCP/WEB
Operating Environment0~40℃
Storage Environment-20℃~60℃
Dimensions1100mm×72mm×157mm
Mounting MethodScrew mounting or DIN rail


ModelAD-DLH120-4Description
Input VoltageAC100~240V/50Hz
Input Current4.2A/115VAC

2.1A/230VAC
Number of Channels4 Channels
Output VoltageDC48V
Instantaneous Max. Current20A/ch
Light Emission ModeStrobe
External TriggerEdge TriggerDefault rising edge trigger, can be set to falling edge; trigger signal voltage 5-24V
Internal TriggerSoftware TriggerSend trigger command via communication port (5-24V)
Self-TriggerAutomatically outputs light source signal based on specified pulse width and cycle
Self-Trigger Cycle1ms~1000msSet the cycle time for each channel via software
Trigger Frequency1~1500HzExternal trigger signal frequency range
Trigger Delay1ms~300msSet via software
Delay Pulse Width1μs~1000μsSet via software
Response Time<10μsDelay time from external trigger input to light source output
Response Frequency≤1500HzMaximum frequency of the external trigger signal
Output Signal4 Channels0-5V level signal, maximum output current 10mA
Communication MethodRS232/TCP/WEB
Operating Environment0~40℃
Storage Environment-20℃~60℃
Dimensions1100mm72mm157mm
Mounting MethodScrew mounting or DIN rai


Previous:Bore Inspection Lens Next:no more

Guangdong Anda Automation Solutions Co., Ltd.
Address:No. 17, Xiangxidong District Road, Liaobu Town, Dongguan City, Guangdong Province
Copyright ©2017 - 2023 Guangdong Anda Automation Solutions Co., Ltd. Technical support: Dongguan Yiqi Technology