1. Better heat insulation effect - double-layer furnace cavity design;
2. Easy to maintain - detachable temperature zone;
3. Beautiful and generous - the design of the same height of the air outlet and the outer cover;
4. Energy saving and high efficiency - Multi-stage independent temperature control and PID adjustment;
5. High precision - The temperature accuracy can be controlled at ±5°C.
Type | Specifications | iCure-2 | iCure-3 | iCure-4 |
Transmission type | Conveying component height(mm) | ±100 | ||
Conveyor chain height(mm) | 900±20 | |||
Conveyor speed (m/min) | 0.1 - 4 | |||
Conveyor direction | Left→right (standard) □ right→left□ | |||
Maximum load | 8kg/m evenly distributed | |||
Temperature control system | Number of temperature zones | 2 temperature zones (all-in-one body upper cover heating) | 3 temperature zones (all-in-one body upper cover heating) | 4 temperature zones (all-in-one body upper cover heating) |
Temperature range | Room temperature ~100℃ (adjustable within the range) | |||
Temperature zone power | 600W*7 (number of tubes)*2 temperature zones | 600W*7 (number of tubes)*3 temperature zone | 600W*7(number of tubes)*4 temperature zone | |
Temperature rise time(min) | 10 | |||
Temperature control accuracy (℃) | ±5 | |||
Factory requirements | Dimensions | L2000,W1070,H1155 | L3000,W1070,H1155 | L4000,W1070,H1155 |
Power supply | 380V, 50Hz, three-phase five-wire system | |||
Rated power(kw) | 9 | 11 | 18 | |
Optional | Return plate line heating Undertrack heating Back plate line Track width electric adjustment |