1. High temperature control accuracy - each temperature zone works independently;
2. Modularized design - the temperature zone, shift plate, and plate storage mechanism can all be disassembled separately;
3. Ergonomics design - electric door opening (the outer cover furnace is integrated electric front and rear door opening)
4. High- usage - greatly reduce the length of the wire body under the condition of ensuring the curing time
5. High security - built-in combustible gas alarm to prevent dangerous gas from causing harm
6. Double temperature control protection - design with temperature mechanical switch + temperature control switch
7. Using PLC+touch screen control
8. Automaticlly - memory storage board number, output statistics
9. High accuracy of lifting positioning - this Ayong beam fiber controlled lifting
10. Equipped with exhaust gas outlet
11. Equipped with SMEMA communication port: can be used online
Specifications | VCO-20 | VCO-30A | VCO-60 | |
Transmission type | Conveying component height(mm) | 10 | 4 | |
Conveyor height(mm) | 950±20 | 900±20 | 975±20 | |
Conveyor direction | Left→right (standard) □ right→left□ | Top in and bottom out (same side in or out) | ||
Storey height(mm) | 63.5 | 95.25 | 76.2 | |
Number of stored-board layers | 24 layers | 30 layers | 64 layers | |
Maximum number of storage boards (pcs) | 22 | 28 | 60 | |
The height of the upper board (mm) | 50 | 90 | 55 | |
The height of the lower board(mm) | 10 | 15 | ||
The weight of the overboard(kg) | 4 | 8 | 2 | |
Dimensions(mm) | L180×W180 -L350×W350 | L180×W180 -L490×W340 | L120×W120 -L250×W20 | |
Temperature control system | Number of temperature zones | 8 temperature zones | 4 temperature zones | |
Temperature range | Room temperature ~130℃ | |||
Temperature zone power | 1000W*4 (number of tubes) * 8 temperature zones | 1000W*4 (number of tubes) * 4 temperature zones | ||
Temperature rise time (min) | 10 | |||
Temperature control accuracy(℃) | ±2 | |||
Product surface temperature distribution deviation(℃) | ±2 | |||
Factory requirements | Dimensions(mm) | L1750,W1500,H2250 | L2250,W1500,H2600 | L2310,W1230,H2420 |
Weight(kg) | 1850 | 2300 | 1800 | |
Power supply | 380V, 50Hz, three-phase five-wire system | |||
Rated power(kw) | 35 | 40 | 35 | |
Standard configuration | Transportation fault detection Test the number of plates in the furnace Cover switch detection Set the timeout period of the shutdown Seek board interval setting Standby time setting Historical alarm record Equipment output statistics Transmission speed detection |